Microplate washer is used to clear Elisa or microplate reader instead of manual work. And the equipment is widely used in hospitals, blood banks, sanitation and antiepidemic stations, medical labs and so on.
Features
• 8- or12- channel manifolds can be easily fitted to allow washing of single and multiple strips or a complete 96-well plate.
• Be able to wash all types of microplate wells and provide automatic plate calibrator
• Easy to integrate it into laboratory automation system
• Soak and shaking function
Technical Specifications
• Residual Volume:<2ul/well
• Dispense/Wash volume: 50ul-500ul
• Dispensation Error: <2%
• Storage:50 programs
• Plate Type: 48 well plates or strip plate
• Manifods:8- or 12- way available
• Wash Time: 0-99
• Soak Time: 0-3600 seconds
• Shaking time: 0-99 seconds
• Alarming Function: Alarm after washing
• Self-test Function: Automatic location check
• Operating System: English or other languages are available on request
• Output: RS232
• Software: Upgrading allowed at any time
• Monitor: Back-illuminant LCD
• Keypad: Membrane keypad
• Working Temperature: 10 -40degree.centigrade
• Power Supply: 110V 60HZ / 220V 50HZ
Clindiag Systems Co., Ltd is an reputed medical devices manufacturer in China, whose clients mostly distributors are from all over the world. Clindiag offers highly qualified products as well as excellent safter-sale service for its equipment and reagents. Any intrests or questions, please let us know by sophiesun@clindiag.com, clindiagsophie@gmail.com or for instant messaging sunguangping2010@hotmail.com.
With the headquater in Belgium, Clindiag Systems Co., Ltd is an ISO&CE certified company, specialized in developing, manufacturing and marketing IVD products, including Biochemistry Analyzer, Hematology Analyzer, Coagulameter, Electrolyte Analyzer, Microplate Reader(ELISA), Microplate Washer, Urine Analyzer, Micropipettes and all related reagents, all products are of high quality, competitive price and excellent service.
2012年4月1日星期日
2012年3月30日星期五
Clindiag Microplate Reader (MR-96)
Based on the principle of colorimetric method, microplate reader, also called ELISA, is used to test the volume of antigens or antibodies. There are automatic and semi-automatic microplate readers and our semi-qutomatic microplate reader (MR-96) enjoys good fame of simplicity, easy operation and accuracy. You may refer to the descriptions below for furtehr information.
Features
• An 8-channel microplate reader with high sophisticated technology
• High quality, high reliability and easy to operate
• Automatic focusing function makes the testing results more precise
• Tray shaking function
Technical Specifications
• Measuring System: 8 channels
• Wavelength: 405/450/492/630nm
• Linear Measurement Range: 0.001-3.500 Abs
• Photometric Accuracy: ?.02 A
• Repeatability: <0?.0%
• Stability: <0.005 Abs
• Tray Shaking: Yes
• Optical Filters: 578,620nm
• Detector: Automatic focusing function makes the results more precise.
• Interface: RS232 serial port
• Printer: Internal printer
• Analysis Mode: O.D.,cut-off, single and multi-standard(up to 10 calibrators), Mono-bichromatic wavelength, dynamic reading, etc.
• Data processing and memorization: The reader has the function to store
• Test methods. In addition, MR-96 is also able to memorize 200 tests and 1500 tests separately.
• Power Supply: 220V 50HZ
Features
• An 8-channel microplate reader with high sophisticated technology
• High quality, high reliability and easy to operate
• Automatic focusing function makes the testing results more precise
• Tray shaking function
Technical Specifications
• Measuring System: 8 channels
• Wavelength: 405/450/492/630nm
• Linear Measurement Range: 0.001-3.500 Abs
• Photometric Accuracy: ?.02 A
• Repeatability: <0?.0%
• Stability: <0.005 Abs
• Tray Shaking: Yes
• Optical Filters: 578,620nm
• Detector: Automatic focusing function makes the results more precise.
• Interface: RS232 serial port
• Printer: Internal printer
• Analysis Mode: O.D.,cut-off, single and multi-standard(up to 10 calibrators), Mono-bichromatic wavelength, dynamic reading, etc.
• Data processing and memorization: The reader has the function to store
• Test methods. In addition, MR-96 is also able to memorize 200 tests and 1500 tests separately.
• Power Supply: 220V 50HZ
2012年3月28日星期三
Clindiag Electrolyte Analyzer - EA-2/3/5
Clindiag electrolyte analyzers are divided into three model types, EA-2, EA-3, EA-5, and their main differences are shown as below,
EA-2 : K+ Na+
EA-3 : K+ Na+ Cl-
EA-5 : K+ Na+ Cl- Ca2+ PH
So, customers may choose types according to their actual needs.
For further specifications, please refer to the descriptions below.
Features
• Friendly software makes it easy to operate
• Automatic priming and maintenance minimize problems
• Automatic probe cleaning, reducing carry-over
• Automatic standby mode makes it ready to work immediately at any time
• Automatic calibration
• Long-life and stable electrodes
Technical Specifications
• Parameter: EA-2 : K+ Na+ ,EA-3 : K+ Na+ Cl- ,EA-5 : K+ Na+ Cl- Ca2+ PH
• Assay Method: Ion selective electrode
• Throughput: 60 samples/ hr
• Data Storage: More than 2000 samples and Q.C. data
• Sample Type: Whole blood, serum, plasma or urine
• Sample Volume: 120 ul
• Display: 128 mm*64mm back-illuminated LCD
• Printer: Built-in thermal printer, 58 mm width paper
• Output: RS-232
• Environment requirements: Temperature:18-35degree.centigrade, humidity:=85%
• Power Supply: AC 110V 60HZ, 50W / 220V 50HZ
• Dimension: 30cm*25cm*24cm
• Weight: 7.0kg
EA-2 : K+ Na+
EA-3 : K+ Na+ Cl-
EA-5 : K+ Na+ Cl- Ca2+ PH
So, customers may choose types according to their actual needs.
For further specifications, please refer to the descriptions below.
Features
• Friendly software makes it easy to operate
• Automatic priming and maintenance minimize problems
• Automatic probe cleaning, reducing carry-over
• Automatic standby mode makes it ready to work immediately at any time
• Automatic calibration
• Long-life and stable electrodes
Technical Specifications
• Parameter: EA-2 : K+ Na+ ,EA-3 : K+ Na+ Cl- ,EA-5 : K+ Na+ Cl- Ca2+ PH
• Assay Method: Ion selective electrode
• Throughput: 60 samples/ hr
• Data Storage: More than 2000 samples and Q.C. data
• Sample Type: Whole blood, serum, plasma or urine
• Sample Volume: 120 ul
• Display: 128 mm*64mm back-illuminated LCD
• Printer: Built-in thermal printer, 58 mm width paper
• Output: RS-232
• Environment requirements: Temperature:18-35degree.centigrade, humidity:=85%
• Power Supply: AC 110V 60HZ, 50W / 220V 50HZ
• Dimension: 30cm*25cm*24cm
• Weight: 7.0kg
2012年3月25日星期日
Clindiag Hematology Analyzer
Clindiag hematology analyzers are divided into two types - HA-22(for human beings) and HA-Vet(for animals), and both types are highly praised by our clients for easy operation, high quality and competitive price. Below you can see the detailed specifications.
Features
• Easy operation by one button
• Aspiration probe is cleaned automatically to avoid the carry-over
• Whole blood and prediluted blood test modes are available
• The appropriative calibrate program can calculate the peripheral blood and venous blood respectively and save the results automatically
• Internal Real-time monitoring system (continual supervise the micro hole, liquid circulating system and reagent residue), reminding the special results and diagnosing the problem automatically
• Automatic maintenance function and standby function make the analyzer ready to work at any time
• Clog prevention and alarm function
• 24 hours on, have the facility of automatic Suspend model
• Safe reagent without any harm to environment
• HA-Vet is specially designed for veterinary clinic use, with 10 different species of animal blood (Rat, might mouse, guinea pig, rabbit, dog, cat, pig, cow, cattle, bull, buffalo, sheep, goat, monkey, deer, camel, horse and so on).
Technical Specifications
• Automatic: Fully automatic
• Throughput: HA-20/22/ Vet : 60
• Parameter: HA-22/ Vet : 22 parameters, 3 part differential of WBC , HA-20 : 20 parameters, 3 parts differential of WBC
• Sample Volume: 10ul (whole blood), 20ul (prediluted blood)
• Measuring Principle: Electro-impedance, photometric analysis
• Testing Items:
WBC, LY ,LY% ,MO,MO%,GR,GR% HGB,RBC,HCT, MCV,RDW-SD,RDW-CV, MCH, MCHC, PLT, MPV, PCT, PDW
• Linearity Range: WBC: 0.0-99.9 (*103/ul), RBC: 0.0-9.99 (*103/ul), HGB: 0.0-30.0 (g/dl), PLT:0-999 (*103/ul)
• Accuracy (CV %):
WBC= 3.0%, RBC=2.0%, PLT =4.0% HGB = 1.5%, HCT = 2.0%, MCV=1.5% MCH = 2.0%, MCHC=2.0%, PCT= 3.0% MPV= 3.0%,PDW= 3.0%
• Display: 5.7 inch LCD, Touch pad
• Storage: 10000 results with histograms
• Printing Mode: Internal thermal printer or out- connection
• Output: RS232
• Printer: Built-in thermal printer, 58 mm width paper
• Power Supply: 110V 60HZ / 220V 50HZ, 60VA
• Dimension: 33cm*38cm*50cm
• Weight: 15 kg
Features
• Easy operation by one button
• Aspiration probe is cleaned automatically to avoid the carry-over
• Whole blood and prediluted blood test modes are available
• The appropriative calibrate program can calculate the peripheral blood and venous blood respectively and save the results automatically
• Internal Real-time monitoring system (continual supervise the micro hole, liquid circulating system and reagent residue), reminding the special results and diagnosing the problem automatically
• Automatic maintenance function and standby function make the analyzer ready to work at any time
• Clog prevention and alarm function
• 24 hours on, have the facility of automatic Suspend model
• Safe reagent without any harm to environment
• HA-Vet is specially designed for veterinary clinic use, with 10 different species of animal blood (Rat, might mouse, guinea pig, rabbit, dog, cat, pig, cow, cattle, bull, buffalo, sheep, goat, monkey, deer, camel, horse and so on).
Technical Specifications
• Automatic: Fully automatic
• Throughput: HA-20/22/ Vet : 60
• Parameter: HA-22/ Vet : 22 parameters, 3 part differential of WBC , HA-20 : 20 parameters, 3 parts differential of WBC
• Sample Volume: 10ul (whole blood), 20ul (prediluted blood)
• Measuring Principle: Electro-impedance, photometric analysis
• Testing Items:
WBC, LY ,LY% ,MO,MO%,GR,GR% HGB,RBC,HCT, MCV,RDW-SD,RDW-CV, MCH, MCHC, PLT, MPV, PCT, PDW
• Linearity Range: WBC: 0.0-99.9 (*103/ul), RBC: 0.0-9.99 (*103/ul), HGB: 0.0-30.0 (g/dl), PLT:0-999 (*103/ul)
• Accuracy (CV %):
WBC= 3.0%, RBC=2.0%, PLT =4.0% HGB = 1.5%, HCT = 2.0%, MCV=1.5% MCH = 2.0%, MCHC=2.0%, PCT= 3.0% MPV= 3.0%,PDW= 3.0%
• Display: 5.7 inch LCD, Touch pad
• Storage: 10000 results with histograms
• Printing Mode: Internal thermal printer or out- connection
• Output: RS232
• Printer: Built-in thermal printer, 58 mm width paper
• Power Supply: 110V 60HZ / 220V 50HZ, 60VA
• Dimension: 33cm*38cm*50cm
• Weight: 15 kg
2012年3月21日星期三
The Fastest Automatic Biochemistry Analyzer - Clindiag FA-400/400E
FA-400 is the fastest automatic biochemistry analyzer, of which the speed can reach 400 tests/hr. With four plates (1 sample plate, 2 reagent plates and 1 reaction plate) and many other components, the machine is big. If you really need such fast speed, then this machine is the perfect choice.
Below you can see the detailed specifications.
Features
• True random access and direct reading system
• Automatic 8 channels washing station and reusable cuvette
• With refrigerated reagent positions
• Perfect self-checking function
• Liquid level detection sensors for sample and reagent
• FA-400E with ISE unit of K +, Na +, Cl -, electrodes, which are available on request.
• Bar code reader is available on request
• Simplicity of operation and flexibility with user friendly software
• Designed with environmental protection concept
Technical Specifications
• Operation:True random access
• Reading System:Direct reading system
• Assay Type: End point, Kinetic, fixed time, differential, blanking, bichromatic and immunoturbidimetric, 1-2 reagent assays and all users programmable
• Assay Item: Maximum 30/40 chemistry assays and 5 electrolytes assays (ISE unit is optional)
• Throughput: 400 tests/hr or 500 tests/hr with ISE
• Sample Capacity:88sample positions including standard, controls and stat, either serum cup or primary tube available
• Sample Volume:1-100 ul, 0.1 ul/step
• Reagent Capacity: 2*30/40 refrigerated reagent positions(R1:30/40, R2 30/40)
• Reagent Volume:R1:1-500 ul, 1 ul/step; R2:1-500 ul, 1 ul/step
• Reagent Probe:With liquid level detection sensor
• Reaction time:0-999 seconds
• Minimum Reaction Volume:180 ul • Reaction Temperature:37degree.centigrade?.1degree.centigrade
• Cuvette:90 high-quality UV-transmitted plastic cuvettes
• Washing:8 channels automatic washing system for reading cuvette and for each sample/reagent probe equipped with independent washing station
• Calibrator:Linearity and nonlinearity multipoint calibrator
• Sample Dilution/Retest:When the result is out of range or the sample is in sufficient, the sample may be diluted and retested automatically or program retest in advance
• Wavelength:300nm-800nm, 7 measuring wavelengths, two spare ones, others on request
• Width of Band:? nm
• Light Source:Long-life halogen lamp
• Photometric Measuring Range:0-3.000 O.D.
• Star Test:Allowed at any time
• Mixing Function:Yes
• Quality Control:Q.C. processing randomly and Q.C. data can be displayed and printed at any time and stored for years.3-6levels of Q.C. can be run at the same time
• Software:The colorful interface of friendly software with different language versions. Windows xp/2000 makes it easier to operate
• Data Processing:More than 200 assay methods and one million patients? data can be stored for a long time.
• Report Format:4 formats
• Optional accessories:ISE unit, bar code reader for reagent and sample, floor standing cabinet, quartz cuvette
• Power Supply:110V 60HZ / 220V 50HZ
• Dimension:130cm*110cm*90 cm
• Weight:105KGs
Below you can see the detailed specifications.
Features
• True random access and direct reading system
• Automatic 8 channels washing station and reusable cuvette
• With refrigerated reagent positions
• Perfect self-checking function
• Liquid level detection sensors for sample and reagent
• FA-400E with ISE unit of K +, Na +, Cl -, electrodes, which are available on request.
• Bar code reader is available on request
• Simplicity of operation and flexibility with user friendly software
• Designed with environmental protection concept
Technical Specifications
• Operation:True random access
• Reading System:Direct reading system
• Assay Type: End point, Kinetic, fixed time, differential, blanking, bichromatic and immunoturbidimetric, 1-2 reagent assays and all users programmable
• Assay Item: Maximum 30/40 chemistry assays and 5 electrolytes assays (ISE unit is optional)
• Throughput: 400 tests/hr or 500 tests/hr with ISE
• Sample Capacity:88sample positions including standard, controls and stat, either serum cup or primary tube available
• Sample Volume:1-100 ul, 0.1 ul/step
• Reagent Capacity: 2*30/40 refrigerated reagent positions(R1:30/40, R2 30/40)
• Reagent Volume:R1:1-500 ul, 1 ul/step; R2:1-500 ul, 1 ul/step
• Reagent Probe:With liquid level detection sensor
• Reaction time:0-999 seconds
• Minimum Reaction Volume:180 ul • Reaction Temperature:37degree.centigrade?.1degree.centigrade
• Cuvette:90 high-quality UV-transmitted plastic cuvettes
• Washing:8 channels automatic washing system for reading cuvette and for each sample/reagent probe equipped with independent washing station
• Calibrator:Linearity and nonlinearity multipoint calibrator
• Sample Dilution/Retest:When the result is out of range or the sample is in sufficient, the sample may be diluted and retested automatically or program retest in advance
• Wavelength:300nm-800nm, 7 measuring wavelengths, two spare ones, others on request
• Width of Band:? nm
• Light Source:Long-life halogen lamp
• Photometric Measuring Range:0-3.000 O.D.
• Star Test:Allowed at any time
• Mixing Function:Yes
• Quality Control:Q.C. processing randomly and Q.C. data can be displayed and printed at any time and stored for years.3-6levels of Q.C. can be run at the same time
• Software:The colorful interface of friendly software with different language versions. Windows xp/2000 makes it easier to operate
• Data Processing:More than 200 assay methods and one million patients? data can be stored for a long time.
• Report Format:4 formats
• Optional accessories:ISE unit, bar code reader for reagent and sample, floor standing cabinet, quartz cuvette
• Power Supply:110V 60HZ / 220V 50HZ
• Dimension:130cm*110cm*90 cm
• Weight:105KGs
2012年3月19日星期一
Clindiag Fully Automatic Biochemistry Analyzer (FA-300/300E)
Clindiag Systems Co., Ltd, with the HQ in Belgium, has achieved great achievements in designing, developing and selling medical devices, such as hematology analyzer, biochemistry analyzer, coagulometer, electrolyte analyzer, microplate reader, microplate washner and micropipettes of various volumes. All Clindiag products are highly praised by our clients, and we have faith in our bright future.
Features
• True random access and direct reading system
• Automatic 8 channels washing station and reusable cuvette
• With refrigerated reagent positions
• Perfect self-checking function
• Liquid level detection sensors for sample and reagent
• FA-300E with ISE unit of K+, Na+, Cl-, electrodes, which are available on request.
• Bar code reader is available on request
• Simplicity of operation and flexibility with user friendly software
• Designed with environmental protection concept
Technical Specifications
• Operation:True random access
• Reading System:Direct reading system
• Assay Type:End point, Kinetic, fixed time, differential, blanking, bichromatic and immunoturbidimetric, 1-2 reagent assays and all users programmable
• Assay Item: Maximum 30/40 chemistry assays and 5 electrolytes assays(ISE unit is optional)
• Throughput : 300 tests/hr 450 tests/hr with ISE
• Sample Capacity:60 sample positions including standard, controls and stat, either serum cup or primary tube available
• Sample Volume:1-100 ul, 0.1 ul/step
• Reagent Capacity: 30/40 refrigerated reagent positions
• Reagent Volume:1-500 ul, 1 ul/step
• Reagent Probe:With liquid level detection sensor
• Reaction time:0-999 seconds
• Minimum Reaction Volume:180 ul
• Reaction Temperature:37degree.centigrade?.1degree.centigrade
• Cuvette:90 high-quality UV-transmitted plastic cuvettes
• Washing:8 channels automatic washing system for reading cuvette and for each sample/reagent probe equipped with independent washing station
• Calibrator:Linearity and nonlinearity multipoint calibrator
• Sample Dilution/Retest:When the result is out of range or the sample is in sufficient, the sample may be diluted and retested automatically or program retest in advance
• Wavelength:300nm-800nm, 7 measuring wavelengths, two spare ones, others on request
• Width of Band:? nm
• Light Source:Long-life halogen lamp
• Photometric Measuring Range:0-3.000 O.D.
• Star Test:Allowed at any time
• Mixing Function:Yes
• Quality Control:Q.C. processing randomly and Q.C. data can be displayed and printed at any time and stored for years.3-6levels of Q.C. can be run at the same time
• Software:The colorful interface of friendly software with different language versions. Windows xp/2000 makes it easier to operate
• Data Processing:More than 200 assay methods and one million patients? data can be stored for a long time.
• Report Format:4 formats
• Optional accessories:ISE unit, bar code reader for reagent and sample, floor standing cabinet, quartz cuvette
• Power Supply:110V 60HZ / 220V 50HZ
• Dimension:100cm*110 cm*85 cm
• Weight:90KGs
Features
• True random access and direct reading system
• Automatic 8 channels washing station and reusable cuvette
• With refrigerated reagent positions
• Perfect self-checking function
• Liquid level detection sensors for sample and reagent
• FA-300E with ISE unit of K+, Na+, Cl-, electrodes, which are available on request.
• Bar code reader is available on request
• Simplicity of operation and flexibility with user friendly software
• Designed with environmental protection concept
Technical Specifications
• Operation:True random access
• Reading System:Direct reading system
• Assay Type:End point, Kinetic, fixed time, differential, blanking, bichromatic and immunoturbidimetric, 1-2 reagent assays and all users programmable
• Assay Item: Maximum 30/40 chemistry assays and 5 electrolytes assays(ISE unit is optional)
• Throughput : 300 tests/hr 450 tests/hr with ISE
• Sample Capacity:60 sample positions including standard, controls and stat, either serum cup or primary tube available
• Sample Volume:1-100 ul, 0.1 ul/step
• Reagent Capacity: 30/40 refrigerated reagent positions
• Reagent Volume:1-500 ul, 1 ul/step
• Reagent Probe:With liquid level detection sensor
• Reaction time:0-999 seconds
• Minimum Reaction Volume:180 ul
• Reaction Temperature:37degree.centigrade?.1degree.centigrade
• Cuvette:90 high-quality UV-transmitted plastic cuvettes
• Washing:8 channels automatic washing system for reading cuvette and for each sample/reagent probe equipped with independent washing station
• Calibrator:Linearity and nonlinearity multipoint calibrator
• Sample Dilution/Retest:When the result is out of range or the sample is in sufficient, the sample may be diluted and retested automatically or program retest in advance
• Wavelength:300nm-800nm, 7 measuring wavelengths, two spare ones, others on request
• Width of Band:? nm
• Light Source:Long-life halogen lamp
• Photometric Measuring Range:0-3.000 O.D.
• Star Test:Allowed at any time
• Mixing Function:Yes
• Quality Control:Q.C. processing randomly and Q.C. data can be displayed and printed at any time and stored for years.3-6levels of Q.C. can be run at the same time
• Software:The colorful interface of friendly software with different language versions. Windows xp/2000 makes it easier to operate
• Data Processing:More than 200 assay methods and one million patients? data can be stored for a long time.
• Report Format:4 formats
• Optional accessories:ISE unit, bar code reader for reagent and sample, floor standing cabinet, quartz cuvette
• Power Supply:110V 60HZ / 220V 50HZ
• Dimension:100cm*110 cm*85 cm
• Weight:90KGs
2012年3月17日星期六
Clindiag Fully Automatic Biochemistry Analyzer (FA-200/200E)
Fully automatic biochemistry analyzer manufactured by Clindiag Systems Co., Ltd enjoys good fame of relatively simple structure, fast speed, accurate testing results and the most important competitive price! FA-200E, with the extra function of electrolyte analyzer, is a little bit advanced that FA-200 without that function. For futher introductions and specifications, please refer to the descriptions below.
FA-200/200E
Fully Automatic Biochemistry Analyzer
Features
• True random access and direct reading system
• Automatic 8 channels washing station and reusable cuvette
• With refrigerated reagent positions
• Perfect self-checking function
• Liquid level detection sensors for sample and reagent
• FA-200E with ISE unit of K+, Na+, Cl-, electrodes, which are available on request.
• Bar code reader is available on request
• Simplicity of operation and flexibility with user friendly software
• Designed with environmental protection concept
Technical Specifications
• Operation: True random access
• Reading System: Direct reading system
• Assay Type: End point, Kinetic, fixed time, differential, blanking, bichromatic and immunoturbidimetric, 1-2 reagent assays and all users programmable
• Assay Item: Maximum 30/40 chemistry assays and 5 electrolytes assays (ISE unit is optional)
• Throughput : 270tests/hr or 390/hr with ISE
• Sample Capacity: 60 sample positions including standard, controls and stat, either serum cup or primary tube available
• Sample Volume: 1-100 ul, 0.1 ul/step
• Reagent Capacity: 30/40 refrigerated reagent positions
• Reagent Volume: 1-500 ul, 1 ul/step
• Reagent Probe: With liquid level detection sensor
• Reaction time: 0-999 seconds
• Minimum Reaction Volume: 180 ul
• Reaction Temperature: 37degree.centigrade ?.1degree.centigrade
• Cuvette: 90 high-quality UV-transmitted plastic cuvettes
• Washing: 8 channels automatic washing system for reading cuvette and for each sample/reagent probe equipped with independent washing station
• Calibrator: Linearity and nonlinearity multipoint calibrator
• Sample Dilution/Retest: When the result is out of range or the sample is in sufficient, the sample may be diluted and retested automatically or program retest in advance
• Wavelength: 300nm-800nm, 7 measuring wavelengths, two spare ones, others on request
• Width of Band: ? nm
• Light Source: Long-life halogen lamp
• Photometric Measuring Range: 0-3.000 O.D.
• Star Test: Allowed at any time
• Mixing Function: Yes
• Quality Control: Q.C. processing randomly and Q.C. data can be displayed and printed at any time and stored for years.3-6levels of Q.C. can be run at the same time
• Software: The colorful interface of friendly software with different language versions. Windows xp/2000 makes it easier to operate
• Data Processing: More than 200 assay methods and one million patients?data can be stored for a long time.
• Report Format: 4 formats
• Optional accessories: ISE unit, bar code reader for reagent and sample, floor standing cabinet, quartz cuvette
• Power Supply: 110V 60HZ / 220V 50HZ
• Dimension: 100cm*110 cm*85 cm
• Weight: 90KGs
2012年3月14日星期三
Clindiag Fully-automatic Biochemistry Analyzer (FA-120)
FA-120 is Clindiag hotsale product used for blood chemical elements test. This automatic chemistry analyzer has relatively fast speed while saving materials and cost at the same time. So it is cost effective. However, if you are in urgent need of fast speed, you may consider our FA-400, FA300, or FA-200. Any way, you should choose products according to your need.
Features
• Batch analyzer
• End point, kinetic, fixed time, bichromatic, serum blank, 1-2 reagent assays, multi-standard and all users programmable
• Insert stat sample at any time during testing
• With liquid sensor and automatic probe washing avoiding carrying over
• Automatic carry-over control function (patented)
• Reaction tray reusable
• QC data with levey-jennings chart
• External printer, multi printing forms are available
• Intelligent multi task software
• Complete open parameters setup makes the analyzer may work with any kits qualified locally
Technical Specifications
• Sample Capacity: 64 for sample, calibrator/standard and control
• Reagent Capacity: 20 refrigerated reagent positions
• Throughput: 120 tests /hr
• Reading Cuvette: Flow through cell
• Temperature Precision: 37degree.centigrade ?.1
• Program Memory: Store 200 test programs and more than one million test results
• Calibrator: 1-6 standards
• Optical system: Light Source: 6V/10W long-life halogen lamp
Filter: 7 high quality narrow band filters and 2 more open filter positions.
Wavelength Range: 340nm-750nm
Photometric Measuring Range: 0-3.0 O.D
• Diluter: 1000ul, 1.0ul/step
• Reaction Tray: 96 reaction cuvettes placed in temperature controlled incubator
• External Devices: Pentium IV pc, printer monitor
• Power Supply: 110V 60HZ / 220V 50HZ
• Software: Windows XP/2000
If you have any intrest of our products, feel free to let us know. sophiesun@clindiag.com, clindiagsophie@gmail.com, guangpingsun@yahoo.cn, sunguangping2010@hotmail.com
Features
• Batch analyzer
• End point, kinetic, fixed time, bichromatic, serum blank, 1-2 reagent assays, multi-standard and all users programmable
• Insert stat sample at any time during testing
• With liquid sensor and automatic probe washing avoiding carrying over
• Automatic carry-over control function (patented)
• Reaction tray reusable
• QC data with levey-jennings chart
• External printer, multi printing forms are available
• Intelligent multi task software
• Complete open parameters setup makes the analyzer may work with any kits qualified locally
Technical Specifications
• Sample Capacity: 64 for sample, calibrator/standard and control
• Reagent Capacity: 20 refrigerated reagent positions
• Throughput: 120 tests /hr
• Reading Cuvette: Flow through cell
• Temperature Precision: 37degree.centigrade ?.1
• Program Memory: Store 200 test programs and more than one million test results
• Calibrator: 1-6 standards
• Optical system: Light Source: 6V/10W long-life halogen lamp
Filter: 7 high quality narrow band filters and 2 more open filter positions.
Wavelength Range: 340nm-750nm
Photometric Measuring Range: 0-3.0 O.D
• Diluter: 1000ul, 1.0ul/step
• Reaction Tray: 96 reaction cuvettes placed in temperature controlled incubator
• External Devices: Pentium IV pc, printer monitor
• Power Supply: 110V 60HZ / 220V 50HZ
• Software: Windows XP/2000
If you have any intrest of our products, feel free to let us know. sophiesun@clindiag.com, clindiagsophie@gmail.com, guangpingsun@yahoo.cn, sunguangping2010@hotmail.com
2012年3月13日星期二
Clindiag Semi-automatic Biochemistry Analyzer (SA-20)
Clindiag SA-20 has so many advantages, and below you can see the specifications.
Features
• End point, kinetic, fixed time, mutistandard, bichromatic etc
• Filter wavelengths: 7standard filters from 340 to 800nm, 2 more open filter positions, others are available on request
• With 20 incubating positions
• Large memory to store 200 test programs and 1000 testing results
• Excellent Q.C function Q.C. chart can be stored, displayed and printed.
Technical Specifications
• Reading Cuvette: Both through cell and direct reading cuvette
• Incubating Positions: 20 incubation positions
• Photometric System:
Light Source: 6V 10W long-life halogen lamp
Filters: 7standard filters from 340 to 800nm, 2 more open filter positions; ±2 nm pass-band
Wavelength Accuracy: ±2 nm
• Measuring System: Measuring Range: 0-3.500 O.D
Photometric Linearity: ±2% from 0 to 2.000 O.D.
Photometric Accuracy: ±2% from 0 to 2.000 O.D.
Drift: less than 0.001 O.D.
Carry Over: ≤1%
• Incubator Temperature control: 25degree.centigrade ,30degree.centigrade ,37degree.centigrade, Precision:±0.1degree.centigrade
• Reagent Volume: 200-500 ul
• Printer: Built-in thermal printer, 57mm width paper
• Power Supply: 110V 60HZ / 220V 50HZ, 60VA
• Dimensions: 34cm*38cm*18cm
• Weight: 8.5kg
If you are intrested in our products, don't hesitate to let me know. Email me at sophiesun@clindiag.com, clindiagsophie@gmail.com, or add me to your instant mesaging: guangpingsun2010@hotmail.com, guangpingsun@yahoo.cn
Features
• End point, kinetic, fixed time, mutistandard, bichromatic etc
• Filter wavelengths: 7standard filters from 340 to 800nm, 2 more open filter positions, others are available on request
• With 20 incubating positions
• Large memory to store 200 test programs and 1000 testing results
• Excellent Q.C function Q.C. chart can be stored, displayed and printed.
Technical Specifications
• Reading Cuvette: Both through cell and direct reading cuvette
• Incubating Positions: 20 incubation positions
• Photometric System:
Light Source: 6V 10W long-life halogen lamp
Filters: 7standard filters from 340 to 800nm, 2 more open filter positions; ±2 nm pass-band
Wavelength Accuracy: ±2 nm
• Measuring System: Measuring Range: 0-3.500 O.D
Photometric Linearity: ±2% from 0 to 2.000 O.D.
Photometric Accuracy: ±2% from 0 to 2.000 O.D.
Drift: less than 0.001 O.D.
Carry Over: ≤1%
• Incubator Temperature control: 25degree.centigrade ,30degree.centigrade ,37degree.centigrade, Precision:±0.1degree.centigrade
• Reagent Volume: 200-500 ul
• Printer: Built-in thermal printer, 57mm width paper
• Power Supply: 110V 60HZ / 220V 50HZ, 60VA
• Dimensions: 34cm*38cm*18cm
• Weight: 8.5kg
If you are intrested in our products, don't hesitate to let me know. Email me at sophiesun@clindiag.com, clindiagsophie@gmail.com, or add me to your instant mesaging: guangpingsun2010@hotmail.com, guangpingsun@yahoo.cn
Clindiag Semi-automatic Biochemistry Analyzer (SA-10)
|
Features
|
||
|
||
|
Technical Specifications
|
||
|
2012年3月11日星期日
Clindiag Double-channel Coagulometer - CA-02
|
This semi-automatic coagulometer is designed and developed by Clindiag Systems China. Wirh double channels, the speed is much higher and the testing result is more accurate. Check the following characterictics and see whether the product suits you.
Features
|
||
|
2012年3月9日星期五
Clindiag CA-01 - One Channel Coagulometer
Clindiag coagulometers, including one channel (CA-01) and double channel (CA-02) are both automatic medical devices. With many advantages as follows, they have been warmly welcomed and praised by our customers.
|
Features
|
|
|
Technical Specifications
|